• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Liu, Yongwang (Liu, Yongwang.) | Li, Xing (Li, Xing.) | Yang, Yanling (Yang, Yanling.) (Scholars:杨艳玲) | An, Dongzi (An, Dongzi.) | Ren, Jiawei (Ren, Jiawei.) | Zhou, Zhiwei (Zhou, Zhiwei.) (Scholars:周志伟) | Jia, Ruibao (Jia, Ruibao.) | Song, Wuchang (Song, Wuchang.)

Indexed by:

EI Scopus PKU CSCD

Abstract:

To investigate the main factor that influenced membrane fouling in ultrafiltration, a simulated process of powdered activated carbon and ultrafiltration (PAC/UF) was used to treat micro-polluted raw water and the sedimentation effluent. Membrane fouling characteristics of two samples, effect of particle size and dissolved organic matter on membrane fouling were investigated. The results indicated that PAC/UF process could mitigate the membrane fouling of the sedimentation effluent, but it could not alleviate the membrane fouling of raw water. Organics in the raw water were mostly hydrophilic organic-based small molecules, and it could not mitigate the membrane fouling of the raw water although the aromaticity and the dissolved microbiological products were reduced with the adsorption of PAC particles, which indicated that the adsorbed organic did not cause serious membrane fouling in the raw water. The particles in raw water, with a small particle size and high number, was thought to be the main factor that leading to the invalid fouling control function of PAC/UF process on raw water. Particle number and particle size distribution have a critical role in membrane fouling.

Keyword:

Membranes Organic compounds Water treatment Ultrafiltration Sedimentation Particle size analysis Activated carbon Effluents Membrane fouling Elementary particles Particle size Biogeochemistry

Author Community:

  • [ 1 ] [Liu, Yongwang]College of Architecture and Civil Engineering, Beijing University of Technology, 100124 Beijing, China
  • [ 2 ] [Li, Xing]College of Architecture and Civil Engineering, Beijing University of Technology, 100124 Beijing, China
  • [ 3 ] [Yang, Yanling]College of Architecture and Civil Engineering, Beijing University of Technology, 100124 Beijing, China
  • [ 4 ] [An, Dongzi]Beijing Shougang International Engineering Technology Co., Ltd., 100043 Beijing, China
  • [ 5 ] [Ren, Jiawei]College of Architecture and Civil Engineering, Beijing University of Technology, 100124 Beijing, China
  • [ 6 ] [Zhou, Zhiwei]College of Architecture and Civil Engineering, Beijing University of Technology, 100124 Beijing, China
  • [ 7 ] [Jia, Ruibao]Ji'nan Water and Wastewater Monitoring Cent, 250021 Ji'nan, China
  • [ 8 ] [Song, Wuchang]Ji'nan Water and Wastewater Monitoring Cent, 250021 Ji'nan, China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

Journal of Harbin Institute of Technology

ISSN: 0367-6234

Year: 2014

Issue: 2

Volume: 46

Page: 98-103

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Online/Total:892/5290220
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.