Indexed by:
Abstract:
A biofilter reactor filled with lava as a carrier is used under the condition of room temperature (8-25°C) and low ρ(NH4+-N) (60-90 mg/L). The NO2--N is accumulated through the method of aeration control in the reactor, and its accumulation rate can reach more than 80% after startup. Results show that DO control is the main approach for realizing nitrosification whereas the restraining of free ammonia can be the assistant method for choosing ammonia oxidization bacteria (AOB), and HRT adjusting is the key way to control the result of ρ(NH4+-N) / ρ(NO2--N). According to the experiment result, the changes of ρ(NH4+-N), ρ(NO2--N), and ρ(NO3--N) all have the dynamics characteristics of zero-grade reaction. Furthermore, the conversion rate of NH4+-N is 4.32 mg/(L·h), and the accumulation rates of NO2--N and NO3--N are 3.05 and 0.40 mg/(L·h), respectively. Accordingly, the HRT for partial nitrosification should be controlled from 9 to 14 h.
Keyword:
Reprint Author's Address:
Email:
Source :
Journal of Beijing University of Technology
ISSN: 0254-0037
Year: 2012
Issue: 1
Volume: 38
Page: 121-125
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 2