A multiple energy source air-conditioning system was developed for large office buildings in Beijing, China to reduce the energy consumption and improve the energy utilization in public buildings. Three systems are compared with an air source heat pump system, a ground source heat pump coupled with an air source heat pump system and a solar assisted ground source heat pump coupled with an air source heat pump system. Cost-benefit analyses are given for each type of air conditioning system. The building load was computed using the DeST simulation software. Economic indicators are used to evaluate the systems economics in terms of the initial investment, life cycle cost (LCC), operating cost, payback period, energy conservation rate and cooling and heating cost in hourly moments. The results indicate that the multiple energy sources system has better energy conservation and economics. For a solar heating fraction of 40% to building loads, the required solar heat collector area is 135 m(2), the energy conservation rate is 43.18% and the payback period is 2.76 years. Although the initial investment is greater than for the other systems, the operating costs are lower at 65,932 CNY/year and LCC is lowest at 863,300 CNY. The lowest heating costs among the three systems are at 760 CNY/kJ. (C) 2016 Elsevier Ltd. All rights reserved.
关键词:
通讯作者信息:
电子邮件地址:
来源 :
APPLIED THERMAL ENGINEERING
ISSN: 1359-4311
年份: 2016
卷: 107
页码: 709-718
6 . 4 0 0
JCR@2022
ESI学科: ENGINEERING;
ESI高被引阀值:102
中科院分区:1