收录:
摘要:
A single-screw expander has been designed and manufactured independently. Based on this prototype, testing system has been built and performance experiment has been made. In this article, compressed air was used as working fluid and performance test for the prototype was finished at conditions including different rotational speed and different inlet pressure. From the experimental data, it is shown that when inlet pressure less than 0.8MPa the output power increases with the increase of rotational speed because of not enough expansion; when inlet pressure more than 0.8MPa, the every biggest output power is appeared in the condition of rotational speed 2600 rpm. The test results also show that the total efficiency is influenced by rotational speed obviously, and the highest total efficiency of this machine is 69.64% in the condition of 3000 rpm and 15 bar.
关键词:
通讯作者信息:
电子邮件地址:
来源 :
INTERNATIONAL JOURNAL OF GREEN ENERGY
ISSN: 1543-5075
年份: 2015
期: 3
卷: 12
页码: 257-264
3 . 3 0 0
JCR@2022
ESI学科: ENGINEERING;
ESI高被引阀值:174
JCR分区:2
中科院分区:3