摘要:

The BJUT-II VAD (which was previously called the intra-aorta pump) is a novel left ventricular assist device (LVAD) with a special structure and connection with the native heart. The hemodynamic effect of the phase difference of this pump on the cardiovascular system is still unclear. In this work, seven speed waveforms, whose phase differences vary from 0 degrees to 180 degrees, are used to evaluate the hemodynamic effect of change in phase difference on the cardiovascular system. The external work (EW), equivalent afterload (EAL), pulsatile ratio (PR), and mean aortic pressure during diastolic period (MAPD) are chosen to evaluate the hemodynamic state of the circulatory system. Mathematical study results show that the support levels generated by the BJUT-II VAD under various phase differences are comparable. In contrast, EW, EAL, PR, and MAPD are significantly affected by change in phase difference. It is found that EW reaches its maximum value when the phase difference equals 30 degrees. Similarly, EAL declines with increasing phase difference. PR reaches its maximum value when the phase difference is at 60 degrees. In addition, MAPD decreases with increasing phase difference and then achieves its maximum value at 30 degrees. To obtain comprehensive evaluation of the hemodynamic effects of phase difference on the cardiovascular system, a weight detection algorithm (WDA) whose output indicates the hemodynamic state of the circulatory system is also designed, with EW, PR, and MAPD chosen as the inputs. The minimum value of the output of the WDA indicates the optimal hemodynamic state and optimal phase difference for the BJUT-II VAD. According to the output of the WDA, 30 degrees is considered to be the optimal phase difference for the BJUT-II VAD.

关键词:

External work Phase difference Pulsatility ratio Hemodynamics BJUT-II ventricular assist device Equivalent afterload

作者机构:

  • [ 1 ] [Gu, Kaiyun]Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100124, Peoples R China
  • [ 2 ] [Gao, Bin]Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100124, Peoples R China
  • [ 3 ] [Chang, Yu]Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100124, Peoples R China
  • [ 4 ] [Zeng, Yi]Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100124, Peoples R China

通讯作者信息:

  • 常宇

    [Chang, Yu]Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100124, Peoples R China

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

ARTIFICIAL ORGANS

ISSN: 0160-564X

年份: 2014

期: 11

卷: 38

页码: 914-923

2 . 4 0 0

JCR@2022

ESI学科: CLINICAL MEDICINE;

ESI高被引阀值:222

JCR分区:2

中科院分区:3

被引次数:

WoS核心集被引频次: 11

SCOPUS被引频次: 13

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

在线人数/总访问数:422/4965691
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司