Intra-aorta pump is a novel rotary ventricular assist device. Because of the special structure and connection with the native heart, the hemodynamic effect of support mode of this pump on the cardiovascular system is not clear. In this work, three support modes, including constant speed mode, co-pulse mode, and counter-pulse mode, have been designed for the intra-aorta pump to evaluate the hemodynamic effect of different support modes on the cardiovascular system. Simulation results demonstrate that that both co-pulse mode and counter-pulse mode can achieve better unloading performance than constant speed mode. The intra-aorta pump controlled by co-pulse mode is beneficial for improving coronary flow. Moreover, the external work, which is defined as the product of left ventricular pressure and cardiac output, under co-pulse mode is the minimum of the three support modes (0.783w vs. 0.615w vs. 0.702w). The pulsatility ratio, defined as the ratio of the peak-to-peak value of arterial pressure (AP) to the mean arterial pressure value, under co-pulse mode is the maximum of the three modes (24% vs. 32.8% vs. 23.7%). The equivalent afterload value, which is the ratio of pulsatile pressure at the pump inflow and pulsatile pump flow, is larger than other support modes (0.596mmHg.s/mL vs. 0.9704mmHg.s/mL vs. 0.55mmHg.s/mL). In brief, the intra-aorta pump under co-pulse mode support is beneficial for improving myocardial perfusion and restoring pulsatility of AP, while counter-pulse mode is beneficial to the perfusion of vital organs.

关键词:

External work Pulsatility ratio Hemodynamics Equivalent afterload Intra-aorta pump

作者机构:

  • [ 1 ] [Gao, Bin]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing 100124, Peoples R China
  • [ 2 ] [Chang, Yu]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing 100124, Peoples R China
  • [ 3 ] [Xuan, Yanjiao]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing 100124, Peoples R China
  • [ 4 ] [Zeng, Yi]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing 100124, Peoples R China
  • [ 5 ] [Liu, Youjun]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing 100124, Peoples R China

通讯作者信息:

  • 常宇

    [Chang, Yu]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing 100124, Peoples R China

电子邮件地址:

查看成果更多字段

相关关键词:

相关文章:

来源 :

ARTIFICIAL ORGANS

ISSN: 0160-564X

年份: 2013

期: 2

卷: 37

页码: 157-165

2 . 4 0 0

JCR@2022

ESI学科: CLINICAL MEDICINE;

JCR分区:2

中科院分区:3

被引次数:

WoS核心集被引频次: 21

SCOPUS被引频次: 21

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

在线人数/总访问数:172/4508660
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司