Purpose: Gestational hypertension (GH) is a serious health hazard for pregnant women and fetuses. The incidence of GET involves many epidemiological, biochemical, and hemodynamic factors. Methods: The current study investigated the GH risk under the influence of epidemiological, biochemical, and hemodynamic factors, and designed corresponding GET risk evaluation methods and apparatus. Results: The evaluation method has 74.15% sensitivity and 81.84% specificity. The ROC area under the curve is 0.841. The apparatus automatically imports epidemiological, biochemical, and hemodynamic factors, and then expresses the GH risk as numbers, bar codes, and colors through logic array analysis. Conclusion: The GET risk value can effectively give the risk level of GH. The GET risk barcode can improve the degree of automation of information storage, transmission, and identification in GET monitoring. The GET risk color can also improve the GET macro description.
关键词:
通讯作者信息:
电子邮件地址:
来源 :
CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY
ISSN: 0390-6663
年份: 2013
期: 1
卷: 40
页码: 61-65
0 . 2 0 0
JCR@2022
ESI学科: CLINICAL MEDICINE;
JCR分区:4
中科院分区:4