Large space circular coal storage dome (LSCCSD) offers an environmental and dependable alternative to open stockpiles, and it has been consequently widely applied in China. However, due to the lack of scientific guidelines, its natural ventilation performance is lower than expected. Natural ventilation potential strongly depends on the roof geometry and opening mode, which have not yet been investigated for LSCCSD. This paper presents a detailed evaluation of the impact of dome geometry (rise span ratio), opening height, and opening modes on the ventilation performance of LSCCSD. The evaluation is based on computational fluid dynamics (CFD) methods and is validated by available wind tunnel testing. We employed three evaluation indicators, which are wind pressure coefficient, effective ventilation rate, and wind speed ratio. The results demonstrate that the rise span ratio has a significant effect on the wind pressure difference and the effective ventilation rate increases by approximately 9%-42% with a single-annular opening. When double-annular openings are set in a strong positive pressure zone, the effective ventilation rate increases by 100% and the average wind speed ratio increases by 50%. When it is compared with single one with similar opening height, the effective ventilation rate increases by 25%. The optimum natural ventilation performance for LSCCSD is achieved at a rise span ratio of 0.37. In addition, the lateral middle opening is kept higher than the ridge top of the coal pile. The proposed evaluation approach and design parameters provided instructive information in the building design and ventilation control for LSCCSDs.

关键词:

natural ventilation performance computational fluid dynamics large space circular coal storage dome opening mode evaluation indicator

作者机构:

  • [ 1 ] [Hou, Yaohua]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, Beijing 100124, Peoples R China
  • [ 2 ] [Chen, Chao]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, Beijing 100124, Peoples R China
  • [ 3 ] [Zhou, Yu]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, Beijing 100124, Peoples R China
  • [ 4 ] [Hou, Yaohua]China Peoples Police Univ, Dept Fire Commanding, Langfang 065000, Peoples R China
  • [ 5 ] [Yang, Zhixiang]Huadian Heavy Ind Co Ltd, Beijing 100070, Peoples R China
  • [ 6 ] [Wei, Shen]UCL, Bartlett Sch Construct & Project Management, London WC1E 7HB, England

通讯作者信息:

  • 陈超

    [Chen, Chao]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, Beijing 100124, Peoples R China

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

BUILDING SIMULATION

ISSN: 1996-3599

年份: 2020

期: 4

卷: 14

页码: 1077-1093

5 . 5 0 0

JCR@2022

ESI学科: ENGINEERING;

ESI高被引阀值:115

被引次数:

WoS核心集被引频次: 7

SCOPUS被引频次: 5

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

在线人数/总访问数:131/4518535
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司