作者:

Wang, Haoran (Wang, Haoran.) | Anzai, Hitomi (Anzai, Hitomi.) | Liu, Youjun (Liu, Youjun.) (学者:刘有军) | Qiao, Aike (Qiao, Aike.) (学者:乔爱科) | Xie, Jinsheng (Xie, Jinsheng.) | Ohta, Makoto (Ohta, Makoto.)

收录:

EI Scopus SCIE

摘要:

Coronary artery aneurysms (CAAs) have been reported to associate with an increased risk for thrombosis. Distinct to the brain aneurysm, which can cause a rupture, CAA's threat is more about its potential to induce thrombosis, leading to myocardial infarction. Case reports suggest that thrombosis risk varied with the different CAA diameters and hemodynamics effects (usually wall shear stress (WSS), oscillatory shear index (OSI), and relative residence time (RRT)) may relate to the thrombosis risk. However, currently, due to the rareness of the disease, there is limited knowledge of the hemodynamics effects of CAA. The aim of the study was to estimate the relationship between hemodynamic effects and different diameters of CAAs. Computational fluid dynamics (CFD) provides a noninvasive means of hemodynamic research. Four three-dimensional models were constructed, representing coronary arteries with a normal diameter (1x) and CAAs with diameters two (2x), three (3x), and five times (5x) that of the normal diameter. A lumped parameter model (LPM) which can capture the feature of coronary blood flow supplied the boundary conditions. WSS in the aneurysm decreased 97.7% apparently from 3.51 Pa (1x) to 0.08 Pa (5x). OSI and RRT in the aneurysm were increased apparently by two orders of magnitude from 0.01 (1x) to 0.30 (5x), and from 0.38 Pa-1 (1x) to 51.59 Pa-1 (5x), separately. Changes in the local volume of the CAA resulted in dramatic changes in local hemodynamic parameters. The findings demonstrated that thrombosis risk increased with increasing diameter and was strongly exacerbated at larger diameters of CAA. The 2x model exhibited the lowest thrombosis risk among the models, suggesting the low-damage (medication) treatment may work. High-damage (surgery) treatment may need to be considered when CAA diameter is 3 times or higher. This diameter classification method may be a good example for constructing a more complex hemodynamic-based risk stratification method and could support clinical decision-making in the assessment of CAA.

关键词:

作者机构:

  • [ 1 ] [Wang, Haoran]Tohoku Univ, Inst Fluid Sci, Aoba Ku, 2-1-1 Katahira, Sendai, Miyagi 9808577, Japan
  • [ 2 ] [Anzai, Hitomi]Tohoku Univ, Inst Fluid Sci, Aoba Ku, 2-1-1 Katahira, Sendai, Miyagi 9808577, Japan
  • [ 3 ] [Ohta, Makoto]Tohoku Univ, Inst Fluid Sci, Aoba Ku, 2-1-1 Katahira, Sendai, Miyagi 9808577, Japan
  • [ 4 ] [Wang, Haoran]Tohoku Univ, Grad Sch Biomed Engn, Aoba Ku, 6-6 Aramaki Aza Aoba, Sendai, Miyagi 9808579, Japan
  • [ 5 ] [Liu, Youjun]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 100022, Peoples R China
  • [ 6 ] [Qiao, Aike]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 100022, Peoples R China
  • [ 7 ] [Xie, Jinsheng]Capital Med Univ, Beijing Inst Heart Lung & Blood Vessel Dis, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing 100029, Peoples R China
  • [ 8 ] [Ohta, Makoto]Tohoku Univ, Univ Lyon, CNRS, ELyTMaX UMI 3757, Sendai, Miyagi, Japan

通讯作者信息:

  • [Ohta, Makoto]Tohoku Univ, Inst Fluid Sci, Aoba Ku, 2-1-1 Katahira, Sendai, Miyagi 9808577, Japan;;[Ohta, Makoto]Tohoku Univ, Univ Lyon, CNRS, ELyTMaX UMI 3757, Sendai, Miyagi, Japan

电子邮件地址:

查看成果更多字段

相关关键词:

相关文章:

来源 :

COMPLEXITY

ISSN: 1076-2787

年份: 2020

卷: 2020

2 . 3 0 0

JCR@2022

ESI学科: MATHEMATICS;

ESI高被引阀值:46

被引次数:

WoS核心集被引频次: 13

SCOPUS被引频次: 9

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 4

在线人数/总访问数:926/3887335
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司