Abstract:
In this part of study, the comparative observations of the structure and the surface temperature of the frost layer of both the coated and uncoated surfaces ware carried out and a preliminary analysis was presented. A series of the repeated cycling tests were completed that lasted for more than 2 months, and the influences of the coating thickness were also investigated. The results show that the frost layer deposited on the coating surface has a very fragile structure and can be removed easily by external force. The coating thickness has an important effect on the anti-frosting performance of the paint. The results also show that the coating of the paint on the copper surface is durable and presents a very good repeated cycling performance. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
Keyword:
Reprint Author's Address:
Email:
Source :
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
ISSN: 0140-7007
Year: 2006
Issue: 2
Volume: 29
Page: 237-242