Indexed by:
Abstract:
In this paper, a frequency analysis for the microcirculation model is introduced to find new microcirculation parameters in the frequency domain. By using Bode Plot of transfer function, we found two characteristic parameters of the model: damping ratio xi and break frequency omega(n). By analyzing the variation of xi and omega(n), it enables us to have better understanding of different states of microcirculation. At low damping, 0 = 1, the state of microcirculation will be worse and worse along with the descending of the omega(n). The results of experiments on 120 subjects are consistent with the analytical results of the model.
Keyword:
Reprint Author's Address:
Email:
Source :
BIO-MEDICAL MATERIALS AND ENGINEERING
ISSN: 0959-2989
Year: 2005
Issue: 3
Volume: 15
Page: 189-197
1 . 0 0 0
JCR@2022
ESI Discipline: CLINICAL MEDICINE;
JCR Journal Grade:4
Cited Count:
WoS CC Cited Count: 2
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0
Affiliated Colleges: