In this paper, the design principle for the connection of prefabricated steel plate shear wall with beam-only-connected infill plate is investigated. Expressions for determining single-bolt demands for the purposes of design are developed, and a multicover plates connection for prefabricated steel plate shear wall with beam-only-connected infill plate is designed. The lateral resistant behavior for both welded connections and multicover plates connections for steel plate shear wall with beam-only-connected infill plate are analyzed and compared by using ABAQUS finite-element software. The effects of changes in the bolt pre-tightening force for multicover plates connection are investigated as well. Then, the FEM simulation results are verified by monotonic loading test of a multicover plates connection with 6 mm infill plate, the lateral resistant behavior and the deformation of cover plates for both FEM simulation results and test results are compared. The results show that the lateral resistant capability of beam-only-connected steel plate shear wall with prefabricated multicover plates connection is less than that with welded connection; in tension field, severe tearing happens on the bolt holes, and the loss of bolt pre-tightening force is large; the tearing of bolt holes and the loss of bolt pre-tightening force get smaller when they are away from the tension field; the buckling of infill plate can cause deformation in cover plates. There was no significant difference on force transmission performances between welded connections and prefabricated multicover plates connections.