收录:
摘要:
Urban underground tunnels usually have lager traffic volumes and complex structures comparing with other kinds of tunnel. This can give higher fire risk and also make smoke control to become more difficult once the fire occurs. The effect of the fire size and intersection angle on the smoke spread and smoke mass flow distribution in underground urban tunnel with horizontal junctions are studied by the numerical simulation in this paper. The results show that the power size can affect the smoke spread heavily, but it has little effect on the smoke mass flow distributions between the downstream main tunnel and the branch tunnels. Variation of the intersection angle almost have an effect on the smoke spread in upstream main tunnel, but its effect on the smoke spread and smoke mass flow distributions in branch tunnel cannot be neglect. The results are expected to be useful for the smoke control system design in these kinds of tunnels. (C) 2014 The Authors. Published by Elsevier Ltd.
关键词:
通讯作者信息:
电子邮件地址:
来源 :
2013 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING (ICPFFPE 2013)
ISSN: 1877-7058
年份: 2014
卷: 71
页码: 441-445
语种: 英文