Jian, Yiwen (Jian, Yiwen.) | Zhu, Zan (Zhu, Zan.)

收录:

CPCI-S

摘要:

Understanding of sealing performance of rural housing is very important in reducing energy consumption for heating demand. This paper illustrates the identification of infiltration rates through windows and doors in rural housing through temperature measurements. Room air temperatures were measured hourly from 2009-02-08 to 2009-02-17 in one rural housing in Beijing. During the measuring period, there is no one living in this house and all the windows and doors have been closed. The room air temperatures were simulated using DeST-h. The infiltration rate at each hour was identified by minimizing the gap between the measured temperature and the simulated temperature.

关键词:

simulated temperature sealing performance rural housing DeST sofeware measured temperature

作者机构:

  • [ 1 ] [Jian, Yiwen]Beijing Univ Technol BJUT, Dept Bldg Environm & Facil, Beijing, Peoples R China
  • [ 2 ] [Zhu, Zan]Beijing Univ Technol BJUT, Dept Bldg Environm & Facil, Beijing, Peoples R China

通讯作者信息:

  • [Jian, Yiwen]Beijing Univ Technol BJUT, Dept Bldg Environm & Facil, Beijing, Peoples R China

电子邮件地址:

查看成果更多字段

相关关键词:

相关文章:

来源 :

2010 THE SECOND CHINA ENERGY SCIENTIST FORUM, VOL 1-3

年份: 2010

页码: 760-764