Fu Minrui (Fu Minrui.) | Liu Gang (Liu Gang.) | Wang Weining (Wang Weining.) | Gao Bin (Gao Bin.) | Ji Bingyang (Ji Bingyang.) | Chang Yu (Chang Yu.) (学者:常宇) | Liu Youjun (Liu Youjun.) (学者:刘有军)

收录:

SCIE PubMed

摘要:

The STM CP-24 I centrifugal pump is a newly developed centrifugal pump for extracorporeal membrane oxygenation equipment. This study aimed to combine hydraulic experiments, hemodynamic numerical simulations, and standard in vitro hemolysis experiments to investigate the comprehensive performance of this centrifugal pump.In vitro experiments were first done to obtain the pressure-flow data of the centrifugal pump in its working range to evaluate its hydraulic performance. Next, the commonly used clinical working points were selected as boundary conditions, and a computational fluid dynamics method was applied to evaluate its hemodynamic performance. The blood pressure distribution, blood flow fields, and high-wall-shear-stress zones in the centrifugal pump were determined as indicators for hemodynamic evaluation. Finally, standard in vitro hemolysis experiments were performed to test the blood compatibility of this centrifugal pump (n=3 blood samples). In addition, its blood compatibility was evaluated in the form of the normalized index of hemolysis (NIH).The pressure-flow curve of the centrifugal pump showed that the head pressure and flow of the centrifugal pump showed a mostly linear relationship within the whole working range. When the rotation speed of the centrifugal pump was 5,500 rpm, it achieved a hydraulic performance of 550 mmHg head pressure and 8 L/min output flow, which could meet the clinical needs of extracorporeal membrane oxygenation. Analysis of computational fluid dynamics data indicated that the centrifugal pump had excellent hemodynamic performance: even distribution of blood pressure in the pump, no blood flow stagnation zone or dead zone in the overall flow field, and secondary flows in the gap between the rotor and the volute that significantly reduced the volume of the low-blood-flow zone close to the impeller. There was no obvious high-shear-stress zone on the surface of the volute or the impeller, which will effectively reduce the risk of thrombosis. In vitro hemolysis experiments indicated that the centrifugal pump had excellent blood biocompatibility, with a NIH =0.0125±0.0022 g/100 L.The STM CP-24 I centrifugal pump has excellent hydraulic performance, a reasonable design of the hemodynamic structure of the blood pump, and excellent blood compatibility. Therefore, it can meet clinical needs.

关键词:

normalized index of hemolysis (NIH) Centrifugal pump hemolysis hemodynamics

作者机构:

  • [ 1 ] [Fu Minrui]Faculty of Environment and Life, Beijing University of Technology, Beijing, China
  • [ 2 ] [Liu Gang]State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
  • [ 3 ] [Wang Weining]Faculty of Environment and Life, Beijing University of Technology, Beijing, China
  • [ 4 ] [Gao Bin]Faculty of Environment and Life, Beijing University of Technology, Beijing, China
  • [ 5 ] [Ji Bingyang]State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
  • [ 6 ] [Chang Yu]National Clinical Research Center for Child Health, The Children's Hospital Zhejiang University School of Medicine, Hangzhou, China
  • [ 7 ] [Liu Youjun]Faculty of Environment and Life, Beijing University of Technology, Beijing, China

通讯作者信息:

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

Annals of translational medicine

ISSN: 2305-5839

年份: 2021

期: 8

卷: 9

页码: 679

JCR分区:3

被引次数:

WoS核心集被引频次: 0

SCOPUS被引频次:

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

归属院系:

在线人数/总访问数:1165/3899638