摘要:
With flat heat pipe (micro-heat pipe array) as the core component, a new type of PV/T-air collecting evaporator and direct-expansion PV/T-air source heat pump system were designed and built to realize the functions of year-round water heating, winter heating, summer cooling and year-round photovoltaic power production. Experimental study on the performance of heat pump system under the weather conditions from March to May in Beijing was carried out in different operating models (S, SA and A).The experimental results show that the COPS of model S, SA and A is 4.8, 4.2 and 3.8,the η of three models is 109.7%, 125.9% and 32.4% under typical working conditions, which means under the condition of solar irradiation, the performance of the multienergy complementary system in mode S and SA is better than that in mode A. The new heat pump system has a significant performance, and the experimental results provide basic data support for its application. © All Right Reserved.