收录:
摘要:
The common energy efficiency model of chiller in subway station has nonlinear interference, which leads to low prediction accuracy and reliability. To solve the above problems, this paper proposes a model of chiller efficiency prediction based on error correction. This model focuses on the error, trains the historical data of prediction error by SVR, and then corrects the prediction result of traditional model to get the final prediction value of energy efficiency. Through the verification of operation data from air conditioning units on a Beijing subway platform , the results show that this model is superior to the traditional model , the average relative error of predictive value decreased from 4.04*10(-2) to 6.69*10(-)(11).
关键词:
通讯作者信息:
电子邮件地址:
来源 :
PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC)
ISSN: 2161-2927
年份: 2019
页码: 1660-1665
语种: 英文
归属院系: