摘要:
In order to reduce process complexity and manufacturing difficulty, we proposed to use a single air distribution plate to guide the flow and achieve uniform air distribution. We established a three-dimensional model with a size ratio of 1:1 to simulation flow pattern. The optimization results revealed that it is feasible to implement our assumption. After the asterisk plate's optimization, the area uniformity index in the catalytic section was maintained above 0.92 with a maximum value of 0.95, the relative standard deviation was lower than 0.2, and the minimum value was 0.123; and the pressure drop was less than 3.00 Pa, which is in line with the actual use requirements. Among them, Asterisk I with a 30 mm thickness and 15 mm right shift has the best optimization effect. (c) 2021 American Society of Civil Engineers.