摘要:

Precast reinforced concrete (RC) bridge columns are critical substructure components for Accelerated Bridge Construction (ABC), which attracts significant attention all over the world in recent decades. However, seismic behavior of precast RC bridge columns in corrosive environment and related retrofit methods are rarely studied. To fill out this knowledge gap, in this study, four, 1/4-scaled precast RC bridge columns of various corrosion levels were designed, constructed and tested in a pseudo-static manner to gain in-depth understanding of corrosion on the seismic behavior of this type of columns. Two of these columns with higher corrosion levels were retrofitted with carbon fiber reinforced polymer (CFRP) fabrics in the plastic hinge zone to assess the effectiveness of this retrofit measure. Corrosion levels of the specimens were obtained through an electrochemical method to accelerate the corrosion process at the plastic region. It was found that corrosion in the reinforcement was uneven across the section and was much severer at the joint of precast bridge columns. It was also found that even the low corrosion level of longitudinal reinforcement (i.e. 7.2%) can result in a significant decrease (i.e. >15%) in the lateral load capacity, energy dissipation, ductility and ultimate displacement. Hence, the retrofit of corroded precast RC bridge columns should be performed at low-level of corrosion. The test results also indicate that corrosion has more adverse effect on the ultimate displacement and ductility than the strength. In addition, retrofitting bridge columns of higher corrosion levels (i.e., >10%) using CFRP jackets could effectively protect the columns from damage in the plastic hinge zones. However, the damage pattern was shifted to fracture of the longitudinal rebars at the column-footing interface, resulting in substantial reduction in the ultimate displacement capacity. Therefore, it is not recommended to retrofit precast RC bridge columns of high corrosion level using CFRP jackets alone.

关键词:

CFRP Corrosion Precast RC bridge columns Quasi-static test Seismic performance

作者机构:

  • [ 1 ] [Wang, Xu]Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing, Peoples R China
  • [ 2 ] [Li, Huaqiang]Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing, Peoples R China
  • [ 3 ] [Wei, Yanjian]Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing, Peoples R China
  • [ 4 ] [Wu, Suiwen]Univ Nevada, Dept Civil & Environm Engn, Reno, NV 89557 USA
  • [ 5 ] [Jia, Junfeng]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing, Peoples R China
  • [ 6 ] [Zhang, Kaidi]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing, Peoples R China
  • [ 7 ] [Bai, Yulei]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing, Peoples R China
  • [ 8 ] [Li, Huaqiang]Tongji Univ, Coll Civil Engn, Shanghai, Peoples R China

通讯作者信息:

  • 贾俊峰

    [Jia, Junfeng]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing, Peoples R China

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

ENGINEERING STRUCTURES

ISSN: 0141-0296

年份: 2021

卷: 245

5 . 5 0 0

JCR@2022

ESI学科: ENGINEERING;

ESI高被引阀值:9

被引次数:

WoS核心集被引频次: 8

SCOPUS被引频次: 12

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 2

归属院系:

在线人数/总访问数:330/2923271
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司