• 综合
  • 标题
  • 关键词
  • 摘要
  • 学者
  • 期刊-刊名
  • 期刊-ISSN
  • 会议名称
搜索

作者:

Li, Hui (Li, Hui.) | Pan, Youlian (Pan, Youlian.) | Qiao, Aike (Qiao, Aike.) (学者:乔爱科) | Liu, Yinglong (Liu, Yinglong.) | Dong, Nianguo (Dong, Nianguo.)

收录:

EI PKU PubMed CSCD

摘要:

Valve transplantation is often used in the treatment of aortic valve insufficiency. However, after surgery, the reconstructed aortic roots have an expansion phenomenon, in which the lack of valve height causes the aortic valve to close again. In this paper, the effects of different aortic valve height design on valve opening and closing performance were studied. The optimal surgical plan was obtained by in vitro numerical simulation, providing technical support and theoretical basis. In this paper, six groups of three-dimensional geometric models with a valve height increment of ± 0.5 mm were established with a root diameter of 26.0 mm and a valve height of 14.0 mm. Through the structural mechanics calculation and analysis of the parameters such as maximum stress, valve area and contact force of the model, reasonable geometrical dimensions are obtained. The study found that the maximum stress values of the six groups of models ranged from 640 to 690 kPa, which was consistent with the results of the literature; the three-group models with valve heights of 13.5 mm, 14.0 mm, and 14.5 mm were within a reasonable range. The contact force value of the 6 groups of leaflets increased with the increase of valve height. Studies have shown that the height of the aortic valve has an effect on the aortic valve closure performance. A valve height that is too small or too large will reduce the aortic systolic valve area and affect the aortic function. Copyright © 2019 by Editorial Office of Journal of Biomedical Engineering.

关键词:

Surgery Blood vessels

作者机构:

  • [ 1 ] [Li, Hui]College of Life Science and Bioengineering, Beijing University of Technology, Beijing; 100124, China
  • [ 2 ] [Pan, Youlian]College of Life Science and Bioengineering, Beijing University of Technology, Beijing; 100124, China
  • [ 3 ] [Qiao, Aike]College of Life Science and Bioengineering, Beijing University of Technology, Beijing; 100124, China
  • [ 4 ] [Liu, Yinglong]Center of Infant Heart, Beijing Anzhen Hospital, Capital Medical University, Beijing; 100029, China
  • [ 5 ] [Dong, Nianguo]Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan; 430022, China

通讯作者信息:

  • 乔爱科

    [qiao, aike]college of life science and bioengineering, beijing university of technology, beijing; 100124, china

电子邮件地址:

查看成果更多字段

相关关键词:

相关文章:

来源 :

Journal of Biomedical Engineering

ISSN: 1001-5515

年份: 2019

期: 2

卷: 36

页码: 199-205

被引次数:

WoS核心集被引频次:

SCOPUS被引频次:

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

在线人数/总访问数:182/4557422
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司