A sodium-potassium ally (45-wt.%-Na and 55-wt.%-K) heat pipe was experimentally tested to investigate the effect of heating powers (800, 1000, 1200, 1400, and 1600W) on start-up and heat transfer performances. The results showed that under the tested operation conditions, the sodium-potassium ally heat pipe presented an optimal start-up performance with the heating power. Within the range of 800-1600W of heating power, the heat pipe could achieve a dynamic equilibrium state of heat transfer as the heat was carried away by cooling water in time, and the heat transfer coefficient of the sodium-potassium ally heat pipe, convective heat transfer coefficients of evaporator and condenser sections almost linearly increased with the heating power. © 2019, Editorial Department of Journal of Aerospace Power. All right reserved.