Indexed by:
Abstract:
An illumination beam with a subwavelength waist and extended focal depth is ideal for terahertz computed tomography. In this paper, a binary terahertz super-oscillatory lens is proposed with a full width at half-maximum of 0.97 A, a focal length of 48 A, a focal depth of 25 A, and a numerical aperture of 0.24. It was designed using the simulated annealing algorithm, fabricated by three-dimensional printing, and applied in continuous-wave terahertz computed tomography operating at 278.6 GHz. When combined with the total variation minimisation algorithm, this setup was able to recognise a hollow cylinder with wall thickness 1.1 A and a bar of diameter 0.93 A inside a chamber, with mean errors of less than 5%. Our approach provides an effective way to enhance the resolution and reconstruction fidelity of terahertz computed tomography and to promote it as an effective tool for non-destructive testing and three-dimensional measurement.
Keyword:
Reprint Author's Address:
Email:
Source :
OPTICS AND LASERS IN ENGINEERING
ISSN: 0143-8166
Year: 2023
Volume: 167
4 . 6 0 0
JCR@2022
ESI Discipline: ENGINEERING;
ESI HC Threshold:19
Cited Count:
SCOPUS Cited Count: 4
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1
Affiliated Colleges: