摘要:

Since the seismic performance of prefabricated underground structures is not yet clear, they not have been constructed in high seismic intensity areas or poor sites. This paper aims to study the applicability of rectangular prefabricated (semi-rigid prefabricated, ASF, and rigid prefabricated, AMT) underground structures in soft soil sites located in high seismic intensity areas. The structures were compared with cast-in-place (CIP) underground structures. Three-dimensional soil-structure interaction advanced finite element models were established to simulate the seismic behavior of the three types of underground structures (ASF, AMT and CIP) constructed in two different sites (soft rock site and soft soil site). The pre-earthquake stress states, dynamic responses, and post-earthquake performance states of the three underground structures were systematically analyzed, considering various static and dynamic conditions. Additionally, the results of dynamic time history were compared with those of the standard procedures available in the literature. The results demonstrated that: i) site conditions have a significant effect on the structures' static and dynamic responses, ii) the seismic response in soft soil site is much larger than that in soft rock site, but the ratio of response of prefabricated underground structures to that of CIP is almost the same for both soft soil and soft rock sites. Furthermore, as the peak ground acceleration in-creases, the percentage difference of inter-story displacement ratio (IDR) between ASF, AMT and CIP under-ground structures in soft soil site decreases, and iii) prefabricated underground structures can be used in both soft rock and soft soil sites. In addition, the seismic performance of ASF is better than that of the AMT structure, which is better than that of the CIP structure. However, when the ASF structure is built in a site with high seismic intensity and poor soil conditions, special consideration must be given to waterproofing measures for wall-slab joints or setting up tongue and groove to improve the connection stiffness and reduce the deformation.

关键词:

Seismic response Splice joint Site condition Prefabricated underground structure Numerical analysis Seismic performance

作者机构:

  • [ 1 ] [Chen, Jinnan]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
  • [ 2 ] [Xu, Chengshun]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
  • [ 3 ] [Du, Xiuli]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
  • [ 4 ] [Chen, Jinnan]Western Univ, Dept Civil & Environm Engn, London, ON, Canada
  • [ 5 ] [El Naggar, Hesham M.]Western Univ, Dept Civil & Environm Engn, London, ON, Canada

通讯作者信息:

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

SOIL DYNAMICS AND EARTHQUAKE ENGINEERING

ISSN: 0267-7261

年份: 2023

卷: 171

4 . 0 0 0

JCR@2022

ESI学科: ENGINEERING;

ESI高被引阀值:19

被引次数:

WoS核心集被引频次: 5

SCOPUS被引频次: 5

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 1

归属院系:

在线人数/总访问数:321/4947710
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司