收录:
摘要:
In accordance with current codes, a single-story single-bay reinforced concrete frame structure in municipal engineering in eight degree fortification area shall be designed as the first grade. This requirement is so rigorous that the designed cross-sectional area is too large. In order to coordinate the revision work of 'Code for seismic design of outdoor water supply, sewerage, gas and heating engineering', experiments have been carried out on six 1:2 scaled single-story single-bay concrete frame models under cyclic loading, the influence of different seismic grades on the seismic performance of structural model was investigated. Simulations using ABAQUS was done under the same loading. The results show that the seismic performance of the fourth grade models meets the seismic standard performance requirements, and the safety margin under second grade is enough. The lateral deformation ability of the single-story single-bay concrete frame is better than the first story in a multi-story structure because its axial compression ratio is small and its colums are all exterior. Seismic grade two is suggested for single-story single-bay concrete frame in municipal engineering in degree eight seismic fortification zone. © 2018, Editorial Office of Journal of Building Structures. All right reserved.
关键词:
通讯作者信息:
电子邮件地址: