To investigate different effects of anaerobic modes on recovery of partial nitrification (PN), two-stage continuous stirred-tank reactors (CSTR)1# and 2# were used at room temperature (20±2). The experiment had three stages (S1, 2 and S3). During S1, 1# was maintained anaerobic/anaerobic (DO: 0-0.1, 0-0.1 mg/L), 2# was maintained anaerobic/oxic (DO: 0-0.1, 0.6-0.8 mg/L). During S2, 1# was maintained oxic/oxic (DO: 0.2-0.4, 0.6-0.8 mg/L), 2# was continually maintained anaerobic/oxic (DO: 0-0.1, 0.6-0.8 mg/L). To investigate stability of PN after recovery, S3 was carried out. During S3, 1# and 2# was maintained oxic/oxic (DO: 1.0-1.2, 1.0-1.2 mg/L). The following paremeters (time of recovery of PN and stability of PN) were investigated. It demonstrated that the recovery time of 1# was shorter than that of 2# by 12 d. However, PN in 2# was more stable when DO increased to 1.0-1.2 mg/L. Efficient PN could be recovered by the mode of first anaerobic/anaerobic (DO: 0-0.1, 0-0.1 mg/L)then oxic/oxic (DO: 0.2-0.4, 0.6-0.8 mg/L). Afterwards, stable PN could be maintained by anaerobic/oxic (DO: 0-0.1, 0.6-0.8 mg/L). © 2017, Editorial Board of Journal of Harbin Institute of Technology. All right reserved.