• 综合
  • 标题
  • 关键词
  • 摘要
  • 学者
  • 期刊-刊名
  • 期刊-ISSN
  • 会议名称
搜索

作者:

Song, Tian-Yi (Song, Tian-Yi.) | Zhu, Di (Zhu, Di.) | Zhou, Hongyuan (Zhou, Hongyuan.) | Xiang, Kai (Xiang, Kai.) | Chen, Zheng (Chen, Zheng.)

收录:

EI Scopus SCIE

摘要:

Blind-bolted connection is a type of new developed prefabricated beam-column connection, which can be used to connect the concrete filled steel tubular (CFST) columns and the steel beams easily. The static and dynamic performance of CFST column to steel beam joints with blind-bolted connections have been well explored, but limited research has been conducted to investigate the fire and post-fire performance of this type of composite joint. In this paper, a series of reversed T-shaped joint fire tests were conducted to investigate the fire and postfire performance of blind-bolted CFST joints with axially restrained steel beams. The influence of restrained effect from adjacent members in the entire frame structure on the response of blind-bolted joints in and after fire could be reasonably considered by the reversed T-shaped joint fire test. The joint temperature, failure modes, beam and column displacements and temperature internal force development during the entire loading and fire stage were recorded and discussed. The test results indicated that the blind-bolted connections showed very good working performance in and after fire, and no bolt shank fracture or bolt pull-out failure was observed. Finite element analysis (FEA) models were established to simulate the fire and post-fire performance of blind-bolted CFST Tshaped joints with axially restrained steel beams, and the joint moment versus relative rotation angle relationship curves of the blind-bolted joints during the entire fire and loading process were extracted and discussed based on the FEA models. The results indicated that the joint negative moment generated by the axially restrained beam boundary in the heating and cooling phases could go up to around 1.4 times the joint negative moment at ambient temperature.

关键词:

Concrete filled steel tube Post -fire performance Fire performance Restrained beam Blind -bolted connection

作者机构:

  • [ 1 ] [Song, Tian-Yi]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
  • [ 2 ] [Zhu, Di]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
  • [ 3 ] [Zhou, Hongyuan]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
  • [ 4 ] [Xiang, Kai]Minist Publ Secur, Tianjin Fire Res Inst, Tianjin 300381, Peoples R China
  • [ 5 ] [Chen, Zheng]Guangxi Univ, Guangxi Key Lab Disaster Prevent & Engn Safety, Nanning 410082, Peoples R China

通讯作者信息:

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

THIN-WALLED STRUCTURES

ISSN: 0263-8231

年份: 2023

卷: 193

6 . 4 0 0

JCR@2022

被引次数:

WoS核心集被引频次:

SCOPUS被引频次: 7

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

归属院系:

在线人数/总访问数:631/4949651
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司