• 综合
  • 标题
  • 关键词
  • 摘要
  • 学者
  • 期刊-刊名
  • 期刊-ISSN
  • 会议名称
搜索

作者:

Qin, Mingyuan (Qin, Mingyuan.) | Chew, Bee Teng (Chew, Bee Teng.) | Han, Xiaofei (Han, Xiaofei.) | Yang, Zhen (Yang, Zhen.) | Cui, Tong (Cui, Tong.) | Deng, Fei (Deng, Fei.) | Pan, Song (Pan, Song.)

收录:

EI Scopus SCIE

摘要:

Specific occupations and activities often require the ability to provide heating in cold open environments. This leads to a conflict between personnel comfort and portable energy usage. However, studies have not fully explored the characteristics of asymmetric intermittent radiation heating in cold open environments. Therefore, a self-developed catalytic combustion radiant heater is used as an intermittent heat source for exploring its optimal intermittent heating strategy. The evaluation indicators, derived from measurements of the 20 participants in the experiment, include overall thermal evaluations, energy consumption, and corrective power (CP). In the study, the transient characterization the traditional CP (CPtrad) yielded results ranging from -0.76 to 1.76 K, with some negative values. Consequently, the concept of continuity and holistic perspective is broadened to accommodate intermittent heating. The newly expanded indicator, named CPinterm, varied from 0.29 to 2.52 K. Subsequently, a functional model linking CPtrad to CPinterm was obtained by polynomial fitting (R2 = 0.77) to simplify the experimental complexity. The model was also validated by data from previous studies on conduction and convection PCS. Following a comprehensive analysis, the optimal heating strategy for the heater was found to be a 40 cm heating distance, 5 min heating time, and 5 min intermittent time. This strategy reduced energy consumption by 50% and increased fuel usage hours by 2 times compared to continuous heating. This study's established indicator offers a viable evaluation method for personal comfort systems implementing intermittent operation strategies.

关键词:

Catalytic combustion heating Personal comfort systems (PCS) Thermal comfort Corrective power Open cold environments Intermittent operation modes

作者机构:

  • [ 1 ] [Qin, Mingyuan]Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
  • [ 2 ] [Chew, Bee Teng]Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
  • [ 3 ] [Han, Xiaofei]Univ Malaya, Fac Built Environm, Ctr Bldg Construction & Trop Architecture BuCTA, Kuala Lumpur 50603, Malaysia
  • [ 4 ] [Yang, Zhen]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing 100124, Peoples R China
  • [ 5 ] [Pan, Song]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing 100124, Peoples R China
  • [ 6 ] [Cui, Tong]Changan Univ, Sch Civil Engn, Xian 710054, Peoples R China
  • [ 7 ] [Deng, Fei]North China Inst Sci & Technol, Sch Econ & Management, Langfang 065201, Peoples R China

通讯作者信息:

  • [Chew, Bee Teng]Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

BUILDING AND ENVIRONMENT

ISSN: 0360-1323

年份: 2024

卷: 252

7 . 4 0 0

JCR@2022

被引次数:

WoS核心集被引频次:

SCOPUS被引频次: 2

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

归属院系:

在线人数/总访问数:356/4964726
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司