作者:

Gu, Kaiyun (Gu, Kaiyun.) | Guan, Zhiyuan (Guan, Zhiyuan.) | Lin, Xuanqi (Lin, Xuanqi.) | Feng, Yunzhen (Feng, Yunzhen.) | Feng, Jieli (Feng, Jieli.) | Yang, Yujie (Yang, Yujie.) | Zhang, Zhe (Zhang, Zhe.) | Chang, Yu (Chang, Yu.) (学者:常宇) | Ling, Yunpeng (Ling, Yunpeng.) (学者:彭凌云) | Wan, Feng (Wan, Feng.)

收录:

EI Scopus SCIE PubMed

摘要:

Background and objective: A gap still exists in the hemodynamic effect of intra-aortic balloon pump (IABP), venoarterial extracorporeal membrane oxygenation (VA-ECMO), and VA-ECMO plus IABP on the blood perfusion of the coronary artery, brain, and lower limb; the relation between heart flow and ECMO flow; and the wall stress of vessels. Methods: A finite-element model of the aorta, ECMO, and IABP was proposed to calculate the mechanical response via fluid-structure interaction. Heart failure (HF), IABP, ECMO, and ECMO plus IABP were utilized to study the effect of support models. Results: For the pressure curve, VA-ECMO weakened the dicrotic notch of pressure compared with HF and the pulsatile index (0.494 vs. 0.706 vs. 0.471 vs. 0.613). IABP, ECMO, and ECMO plus IABP increased the perfusion of the coronary, brain, and renal artery compared with HF. However, ECMO and ECMO plus IABP clearly reduced the blood flow of the left arteria femoralis compared to that of the right arteria femoralis (ECMO: 194.04 vs. 730.80 mL/min; ECMO plus IABP: 342.15 vs. 947.22 mL/min). In addition, the flow of ECMO accessed the renal artery more than the left ventricular flow. Greater ventricular flow perfused to the renal artery at a diastolic period for ECMO plus IABP, especially at the time points of 2.192 s and 2.304 s. Compared to the velocity distribution with ECMO, the flow of the right arteria femoralis was increased in the process of IABP-on. According to these four cases, the stress of the vascular wall was increased for ECMO support at the systolic period. The peak wall stress of ECMO is increased by 20% at 1.68 s. Conclusions: ECMO plus IABP is more conducive to the blood supply than other cases from the result of numerical simulation. The location of blood intersection was generated in the region of the renal artery, which is estimated carefully. (C) 2019 Elsevier B.V. All rights reserved.

关键词:

Fluid-structure interaction Hemodynamics Intra-aortic balloon pump Venoarterial extracorporeal membrane oxygenation

作者机构:

  • [ 1 ] [Gu, Kaiyun]Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
  • [ 2 ] [Guan, Zhiyuan]Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
  • [ 3 ] [Feng, Jieli]Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
  • [ 4 ] [Yang, Yujie]Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
  • [ 5 ] [Zhang, Zhe]Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
  • [ 6 ] [Ling, Yunpeng]Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
  • [ 7 ] [Lin, Xuanqi]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 200120, Peoples R China
  • [ 8 ] [Chang, Yu]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 200120, Peoples R China
  • [ 9 ] [Feng, Yunzhen]Tongji Univ, Shanghai East Hosp, 150 Jimo Rd, Shanghai 100124, Peoples R China
  • [ 10 ] [Wan, Feng]Tongji Univ, Shanghai East Hosp, 150 Jimo Rd, Shanghai 100124, Peoples R China

通讯作者信息:

  • 常宇

    [Zhang, Zhe]Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China;;[Chang, Yu]Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 200120, Peoples R China

查看成果更多字段

相关关键词:

来源 :

COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE

ISSN: 0169-2607

年份: 2019

卷: 182

6 . 1 0 0

JCR@2022

ESI学科: COMPUTER SCIENCE;

ESI高被引阀值:58

JCR分区:1

被引次数:

WoS核心集被引频次: 11

SCOPUS被引频次: 8

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 2

在线人数/总访问数:1163/2911792
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司