收录:
摘要:
The forced convective heat transfer of mixed molten Hitec salts in transversally corrugated tubes with different sets of structural parameters were obtained through experimental study. The enhanced heat transfer mechanism in transversally tubes with different sets of parameters was investigated; the deviations between the fitting correlations under corresponding structural parameters and experimental data were within 10%. In addition, based on the consideration of transversally corrugated structural factors, a general correlation applicable to three sets of structural parameters, which the maximum deviation was -11.8%, was proposed. It was found that the ratio of heat transfer enhancement for transversely corrugated tube which pitch was equal 9 was 1.6 by comparison with the experimental points in smooth tube.
关键词:
通讯作者信息:
电子邮件地址:
来源 :
Journal of Engineering Thermophysics
ISSN: 0253-231X
年份: 2013
期: 5
卷: 34
页码: 927-930
ESI学科: PHYSICS;
JCR分区:3
中科院分区:4