The code for design of outdoor wastewater engineering in China follows the storm sewer system design method of the former Soviet Union, using attenuation coefficient m for amending the catchment concentration time. In view of the method, the paper analyzes that different urban storm intensity formula parameters b, n and surface catchment concentration time t1, flow time t2 in pipes have impact on the design flow Qm/Q0 after using the attenuation coefficient m. The research finds out that Qm/Q0 is an increasing function of b and t1, and a decreasing function of n and t2. The suitable scope of urban storm intensity formula has been severely affected as a result of using the attenuation coefficient m. Depending on the different surface catchment concentration times, the suitable scope of design flow time t2 in pipes has reduced to 57.5-52.5 min. According to the urban storm intensity formula of Beijing, after using attenuation coefficient m, the design flow has reduced 40%-50%.