Experiment is carried out to simulate different loading level element under coupling of stray current and 5%(by mass) chloride solution. When calculating corrosion of reinforcement, the influence of loading should be considered based on Faraday's first law of electrolysis. The corrosion current density was measured by the linear polarization resistance method. The function of corrosion current density was obtained by nonlinear fitting method. Based on the function of corrosion current density, the influence coefficient of loading level to electrochemical equivalent was obtained. The results show that the corrosion current density increases with the increase of stress ratio of concrete structures and through the influence coefficients of electrochemical equivalent the reinforcement corrosion weight can be calculated and the result is in agreement with the actual situation.