Shear wall with concrete filled steel tube columns is a new kind of shear wall, which can fully display the advantages of the big lateral stiffness of concrete shear wall and good seismic behavior of concrete filled steel tube column. In order to bring the advantages into full play and guarantee seismic safety, it is important to design a reasonable shear connection between constructional measures. For studying working performance of connection of constructional measures, experiments of 6 joint models with different connection constructional measures have been done by applying low frequency circle load. The load-carrying capacity, energy dissipation, hysteretic properties and the failure features of each model are contrastively analyzed. The experiment indicates that safe connection between concrete filled steel tube column and concrete shear wall can be assured by adopting reasonable connection of constructional measures.
关键词:
通讯作者信息:
电子邮件地址:
来源 :
Journal of Beijing University of Technology
ISSN: 0254-0037
年份: 2009
期: 5
卷: 35
页码: 603-610