• 综合
  • 标题
  • 关键词
  • 摘要
  • 学者
  • 期刊-刊名
  • 期刊-ISSN
  • 会议名称
搜索

作者:

Li, Dandan (Li, Dandan.) | Zhang, Xiaojing (Zhang, Xiaojing.) | Xie, Jingchao (Xie, Jingchao.) (学者:谢静超) | Liu, Jiaping (Liu, Jiaping.) (学者:刘加平)

收录:

EI

摘要:

This paper attempts to answer the question whether there is any difference in indoor environmental perceptions between people with and without respiratory allergy. First, an online survey was conducted in China inquiring respondents’ sensitivity to changes in environmental factors including indoor air temperature, indoor relative humidity, indoor air freshness, and outdoor air pollution. Totally, 1293 persons from 30 provinces of China participated in the survey, including 478 allergics and 815 non-allergics. From this investigation over 70% of allergics reported themselves to be more sensitive to four respective environmental factors than others, which was statistically higher than the ratio of non-allergics. Secondly, published studies on environmental perceptions of allergics were reviewed. Ten studies were identified and their findings suggest that perception difference of thermal environment between allergics and non-allergics may occur when subjects are not thermally neutral while perception difference of air quality remains unclear. Therefore further research on this question is needed. © 2020, Springer Nature Singapore Pte Ltd.

关键词:

Air conditioning Air quality Allergies Indoor air pollution Surveys

作者机构:

  • [ 1 ] [Li, Dandan]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
  • [ 2 ] [Zhang, Xiaojing]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
  • [ 3 ] [Xie, Jingchao]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
  • [ 4 ] [Liu, Jiaping]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China

通讯作者信息:

  • [zhang, xiaojing]key laboratory of green built environment and energy efficient technology, beijing university of technology, beijing, china

电子邮件地址:

查看成果更多字段

相关关键词:

相关文章:

来源 :

ISSN: 1863-5520

年份: 2020

页码: 239-248

语种: 英文

被引次数:

WoS核心集被引频次: 0

SCOPUS被引频次: 1

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 2

归属院系:

在线人数/总访问数:79/3612485
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司