摘要:
In this study, nickel-base cored wires were prepared by using NiCr strip to wrap metal powders of nickel (Ni), chromium (Cr), molybdenum (Mo), and chromium boron (CrB). Nickel-base coatings were prepared by electric arc spraying. Microstructures of Ni-Cr-Mo and Ni-Cr-B coatings were investigated using scanning electron microscopy (SEM), energy-dispersive analysis (EDAX), and x-ray diffraction (XRD) analysis. The coatings have a compact surface and presented a bonding strength higher than 40 MPa. Potentiodynamic polarization measurements and salt-spray test were carried out to determine the corrosion behavior of the coatings. The results showed that Ni-base coatings containing Mo (5%) or B (2-4%) had better antichlorine ion corrosion performance than that of Ni-base coatings without Mo element, and PS45 (Ni-Cr-Ti) coating. The antichlorine ion corrosion coatings could be used for resolving the corrosion protection problem of the equipment and piping contacting sour, alkali, salt liquid in petrochemical engineering applications. © ASM International.