• 综合
  • 标题
  • 关键词
  • 摘要
  • 学者
  • 期刊-刊名
  • 期刊-ISSN
  • 会议名称
搜索

作者:

Fan, Guangtao (Fan, Guangtao.) | Xie, Jingchao (Xie, Jingchao.) (学者:谢静超) | Yoshino, Hiroshi (Yoshino, Hiroshi.) | Yanagi, U. (Yanagi, U..) | Hasegawa, Kenichi (Hasegawa, Kenichi.) | Kagi, Naoki (Kagi, Naoki.) | Goto, Tomonobu (Goto, Tomonobu.) | Zhang, Qingyuan (Zhang, Qingyuan.) | Wang, Chunyu (Wang, Chunyu.) | Liu, Jiaping (Liu, Jiaping.) (学者:刘加平)

收录:

EI Scopus SCIE

摘要:

China's aging population is growing rapidly. To date, there have been few literatures concerning indoor environment of private houses with older people. This study fully investigated indoor environment in 10 houses (5 urban and 5 rural houses) with older people during heating season in Beijing, China. Each house was assessed for temperature, relative humidity, CO2, PM2.5, CO, NOx, formaldehydes, acetaldehyde, VOCs, SVOCs and fungi. Results indicated older people in urban houses experienced a steadier and warmer thermal environment than those in rural houses, due to the difference of heating devices between urban and rural houses. Indoor CO2 levels mainly increased up to 1000 ppm in the bedroom during sleeping time. For rural houses, indoor fuel combustion contributed to an extremely high PM2.5 and CO level. Formaldehyde, acetaldehyde, toluene, ethylbenzene and xylenes levels in most houses were lower than the limit values. However, the integrated influence of these compounds was unnegligible. TVOC concentrations in four measured houses exceeded the reference value of 600 mu g/m(3). The most frequent fungi was Cladosporium spp. (90%), followed by Penicillium spp. (70%) and Aspergillus spp. (60%). The fungal levels in rural houses were higher than urban houses. These results will be beneficial to improve housing environmental quality for older people in China. (C) 2018 Elsevier B.V. All rights reserved.

关键词:

Elderly people House VOCs Indoor environmental quality Heating period Fungi

作者机构:

  • [ 1 ] [Fan, Guangtao]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, 100 Pingleyuan, Beijing 100124, Peoples R China
  • [ 2 ] [Xie, Jingchao]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, 100 Pingleyuan, Beijing 100124, Peoples R China
  • [ 3 ] [Wang, Chunyu]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, 100 Pingleyuan, Beijing 100124, Peoples R China
  • [ 4 ] [Liu, Jiaping]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, 100 Pingleyuan, Beijing 100124, Peoples R China
  • [ 5 ] [Yoshino, Hiroshi]Tohoku Univ, Dept Architectural & Bldg Sci, Sendai, Miyagi, Japan
  • [ 6 ] [Goto, Tomonobu]Tohoku Univ, Dept Architectural & Bldg Sci, Sendai, Miyagi, Japan
  • [ 7 ] [Yanagi, U.]Kogakuin Univ, Sch Architecture, Tokyo, Japan
  • [ 8 ] [Hasegawa, Kenichi]Akita Prefectural Univ, Dept Architecture & Environm Syst, Akita, Japan
  • [ 9 ] [Kagi, Naoki]Tokyo Inst Technol, Dept Mech & Environm Informat, Tokyo, Japan
  • [ 10 ] [Zhang, Qingyuan]Yokohama Natl Univ, Dept Urban Innovat, Yokohama, Kanagawa, Japan

通讯作者信息:

  • 谢静超

    [Xie, Jingchao]Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient T, 100 Pingleyuan, Beijing 100124, Peoples R China

查看成果更多字段

相关关键词:

来源 :

ENERGY AND BUILDINGS

ISSN: 0378-7788

年份: 2018

卷: 167

页码: 334-346

6 . 7 0 0

JCR@2022

ESI学科: ENGINEERING;

ESI高被引阀值:156

JCR分区:1

被引次数:

WoS核心集被引频次: 34

SCOPUS被引频次: 41

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 2

在线人数/总访问数:2482/4276302