收录:
摘要:
Four steel-plate shear walls were tested on the shaking table. Two of the walls are steel-plate shear walls with concrete-filled steel tube columns and the other two are composite shear walls with concrete-filled steel tube columns and embedded steel-plate. The ratio of height to width is 1.7 and 3.2 respectively. The Taft seismic ground motion was input in the shaking table test. Based on the experiment, dynamic characters, dynamic responses and failure modes of the four specimens in different seismic peak accelerations are contrastively analyzed. The results show that compared with the steel-plate shear walls with concrete-filled steel tube columns, shear walls with concrete-filled steel tube columns and embedded steel-plate have the following characteristics: the dynamic responses are significantly reduced, the seismic behavior is significantly improved.
关键词:
通讯作者信息:
电子邮件地址: