Liu, Kun (Liu, Kun.) | Zhang, Qiang (Zhang, Qiang.) | Li, Xin (Li, Xin.) | Zhao, Changsong (Zhao, Changsong.) | Quan, Xuemin (Quan, Xuemin.) | Zhao, Rugang (Zhao, Rugang.) | Chen, Zongfeng (Chen, Zongfeng.) | Li, Yansheng (Li, Yansheng.)

收录:

Scopus SCIE PubMed

摘要:

Accurate implantation of pedicle screw in spinal deformity correction surgeries is always challenging. We have developed a method of pedicle screw placement in severe and rigid scoliosis with a multi-level 3D printing drill guide template. From November 2011 to March 2015, ten patients (4 males and 6 females) with severe and rigid scoliosis (Cobb angle > 70A degrees and flexibility < 30%)were included. Multi-level template was designed and manufactured according to the part (two or three levels) of the most severe deformity. The drill template was then placed on the corresponding vertebral surface. Then, pedicle screws were carefully inserted along the trajectories. The other screws were placed in free hand. After surgery, the positions of the pedicle screws were evaluated by CT scan and graded for validation. 48 screws were implanted using templates, other 104 screws in free hand, and the accuracies were 93.8 and 78.8%, respectively, with significant difference. The deformity correction ratio was 67.1 and 41.2% in coronal and sagittal plane post-operatively, respectively. The average operation time was 234.0 +/- 34.1 min, and average blood loss was 557 +/- 67.4 ml. With the application of multi-level template, the incidence of cortex perforation in severe and rigid scoliosis decreased and this technology is, therefore, potentially applicable in clinical practice.

关键词:

Computer-assisted surgery Scoliosis Surgical template 3D printing

作者机构:

  • [ 1 ] [Liu, Kun]Hosp Shunyi Dist Beijing, Beijing, Peoples R China
  • [ 2 ] [Zhang, Qiang]Capital Med Univ, Beijing Ditan Hosp, Dept Orthoped, 8 Jingshun East St, Beijing 100015, Peoples R China
  • [ 3 ] [Li, Xin]Capital Med Univ, Beijing Ditan Hosp, Dept Orthoped, 8 Jingshun East St, Beijing 100015, Peoples R China
  • [ 4 ] [Zhao, Changsong]Capital Med Univ, Beijing Ditan Hosp, Dept Orthoped, 8 Jingshun East St, Beijing 100015, Peoples R China
  • [ 5 ] [Quan, Xuemin]Capital Med Univ, Beijing Ditan Hosp, Dept Orthoped, 8 Jingshun East St, Beijing 100015, Peoples R China
  • [ 6 ] [Zhao, Rugang]Capital Med Univ, Beijing Ditan Hosp, Dept Orthoped, 8 Jingshun East St, Beijing 100015, Peoples R China
  • [ 7 ] [Chen, Zongfeng]Third Mil Med Univ, Chongqing, Peoples R China
  • [ 8 ] [Li, Yansheng]Beijing Univ Technol, Coll Electromech Engn, Beijing, Peoples R China

通讯作者信息:

  • [Zhang, Qiang]Capital Med Univ, Beijing Ditan Hosp, Dept Orthoped, 8 Jingshun East St, Beijing 100015, Peoples R China

电子邮件地址:

查看成果更多字段

相关关键词:

来源 :

EUROPEAN SPINE JOURNAL

ISSN: 0940-6719

年份: 2017

期: 6

卷: 26

页码: 1684-1689

2 . 8 0 0

JCR@2022

ESI学科: CLINICAL MEDICINE;

ESI高被引阀值:190

中科院分区:3

被引次数:

WoS核心集被引频次: 55

SCOPUS被引频次: 73

ESI高被引论文在榜: 0 展开所有

万方被引频次:

中文被引频次:

近30日浏览量: 0

在线人数/总访问数:590/3904961
地址:北京工业大学图书馆(北京市朝阳区平乐园100号 邮编:100124) 联系我们:010-67392185
版权所有:北京工业大学图书馆 站点建设与维护:北京爱琴海乐之技术有限公司